Aging Test System for Varistor

Scope: AGTS-III aging test system can produce AC, half-wave, full-wave and DC high voltage. Thermoelectric accelerated aging test can be carried out on Metal Oxygen Varistor. The full current, resistive current, capacitive current are calculated and P-t curve can be displayed online, the test system can meet the requirements of IEC 60099-4 and relevant standards.

image.png

Aging Test System for MOV

image.png


Aging Test System for MOV




Main specifications are as follows

Parameters /Source

AC

Half and full wave

DC

Measurement uncertainty

Voltage

RMS, 0-15kV

RMS, 0-15kV

Average, 0-15kV

±1%

All current

Peak, 0-100mA

Peak, 0-100mA

Average, 0-100mA

±1%

Resistive current

Peak, 0-100mA

Peak, 0-100mA

Average, 0-100mA

±1%

Power loss

Average, 0-100W

Average, 0-100W

Average, 0-100W

±1%

Environment

●  AC voltage : 3kV ;  DC voltage : 3kV

●  Temperature : 85-145℃