Products

Product Center
Impulse Test System In Communication Field
Location: Home/Products/Impulse Test System In Communication Field

10/350 & 8/20 Impulse Current Test System

Scope: ICTS 10/350&8/20 Impulse Current Test System has Crowbar and RLC circuit, it can output 10/350μs impulse current with Crowbar circuit and its current peak reaches 200kA, and 200kA, 8/20μs current wave can also be produced. The test system is used for carrying VPR Test,Residual Voltage Test, ClassⅠ and Class Ⅱ Classification Test, Operating Duty Test and so on. The test system contends the requirements of IEC 61643 and UL 1449 standards.

QQ截图20201201103629.jpg

10/350 and 8/20 impulse current test system



Main specifications are as follows

Impulse current10/350 Impulse Current
8/20 Impulse Current
Impedance
Front Time
Duration Time
Peak
Front Time
Duration Time
Peak
200/50

10μs
(-10,100)%

350μs ± 20%

200kA
10μs
± 10%

20μs ± 10%

200kV
2Ω...
200/30200kA
200kV
2Ω...
150/30

150kA

150kV

2Ω...
150/20150kA
150kV
2Ω...
150/20120kA
120kV
2Ω...
Operating duty test

AC Source: 0-1000V /5-100A. Phase tracking and control accuracy: 0-360° ±5°
DC Source:0-1500V /5-100A                                                                               

StandardIEC61643,UL1449,IEC60060

029-82681326 83204290

Xi’an Highvolt High Voltage Electrical Equipment Institute Co., Ltd

ADDRESS: No.1,Huoju Road, Beilin  District, Xi'an,Shaanxi, China
TEL:86-(0)-82681326   86-(0)-83204290
E-mail: jddyjs@163.com

  • Mobile Station