Scope:LCTS A/B/C/D Lightning Current Test System can output A, B, C, D lightning current components, the test system can carry continuous sequence lightning current test. It can be used in the research of lightning effect and lightning protection of advanced composite materials, structural parts and whole aircraft in aviation field, and the system contends the requirements of IEC and relevant standards.
Continuous Sequence Lightning Current Test System
Main specifications are as follows:
Lightning current | A component | B component | C component | D component |
Peak time | ≤ 50μs | / | / | ≤ 25μs |
Duration time | ≤ 500μs | 5ms | 250ms-1s | ≤ 500μs |
Rated current | 200kA | 2kA | 200-800A | 100kA |
Charge transfer | / | 10C | 200C | / |
Action integra | 2×10⁶A²s | / | / | 0.25×10⁶A²s |
Load | Crowbar, >50mΩ | >50mΩ | >50mΩ | Crowbar, >50mΩ |
ADDRESS: No.1,Huoju Road, Beilin District, Xi'an,Shaanxi, China
TEL:86-(0)-82681326 86-(0)-83204290
E-mail: jddyjs@163.com